Re: Attn Kraftee - help please!!
- From: mike <mikej@xxxxxxxxxxxx>
- Date: Mon, 26 Nov 2007 18:22:01 +0000
Graham. wrote:
Thanks Graham.
Well in a dire emergency where a cable has been damaged
and one wire of both the remaining pairs have each been
open circuit, I have been known to use one wire from each,
but to split them when both pairs are intact? It shouldn't
happen, but your reasoning is sound, so lets pursue it.
If you and your neighbours lines are in split pairs, I would
expect a measure of audio crosstalk.
Moreover, I would expect to hear the ringing waveform
in your earpiece when your neighbours phone is ringing and
vice versa. The degree of these effects would, of course,
depend on the length of cable with the split pairs, but I would
say even a run of 5 meters would be enough to hear when
ringing is present on the other line.
My thoughts as well. Of course for a simple PTSN, the use of odd wires isn't so much of a problem but for BB - well!!
At the moment the house next door has just changed hands and he hasn't got a phone connected so that makes life a bit difficult.
However (if no-one is looking) I might just put a test set on that pair and listen across while shouting on the other!!
Mike
.