Re: New motor wiring problem.
- From: spambait@xxxxxxxxxx (Doug Miller)
- Date: Thu, 26 Jul 2007 12:23:26 GMT
In article <1185422101.616098.79510@xxxxxxxxxxxxxxxxxxxxxxxxxxxx>, Tvfarmer <jeff@xxxxxxxxxxxx> wrote:
I am rebuilding my jet band saw the 3/4 hp motor went and I am
replacing it with a 1.5 hp. I was saving some money and bought a RO
motor(Tiawan) the spec. 115/220 22/11 amps pre wired for 115. I
have wired (conected 115) it according the provided diagram. The motor
rotates about 2 times then pops the built breaker. Any Ideas why
Ummmm.... because you're trying to run a 22A motor on a 20A circuit?
--
Regards,
Doug Miller (alphageek at milmac dot com)
It's time to throw all their damned tea in the harbor again.
.