Re: 13.8V high current power supply - update



On Thu, 11 May 2006 01:04:23 GMT, Allisonnospam@xxxxxxxxxxxxxxxxxxxxxx
wrote:

Limiting inrush current is mostly to protect the diodes as the first
charge the caps. For the first few ac cycles those caps look like a
dead short or mightly close. Under those conditions the diodes have
to stand the short circuit current the transformer can provide which
can easily exceed diode rating if care is not taken.

Also if a toroid mains transformer is used, the transformer start-up
current can be huge for a large (say 1 kVA) transformer, which could
harm the house wiring or burn the fuses in the main distribution
panel.

Depending at what mains cycle phase angle the transformer was
previously disconnected and on what phase angle it is reconnected to
the mains, the start-up peak can be insignificant or the current can
be huge, which is limited just by the copper resistance of the
primary.

Paul OH3LWR

.



Relevant Pages

  • Re: Can I use a 120V Variac to get 220V?
    ... While one might imagine situations where this technique is ... If your caps don't need reforming, ... current through transformer and bleeeder resistors, ... what voltage do you set the variac too? ...
    (rec.radio.amateur.homebrew)
  • Re: Power Supply Rectification and Smoothing
    ... turning the mains off and then on quickly with the transformer core ... transformer to provide a slightly higher voltage say 32V or so. ... sudden load changes. ... I think they only offer 4 different caps. ...
    (sci.electronics.basics)
  • Re: Power Supply Rectification and Smoothing
    ... Consider the filter caps as if they were a 36V lead acid battery. ... This load would constitute the best output filter with the lowest ... turning the mains off and then on quickly with the transformer core ... ball park figure for a reasonably stable load regulation? ...
    (sci.electronics.basics)
  • Re: Problems with custom amp...
    ... >Anyway, it's basically a 50 watt Fender Reverb, single channel style amp. ... >Bassman size output transformer, no choke, yada-yada. ... >power tranny center-tap not connected, ground side of screen supply filter ... >the underrated filter supply caps. ...
    (alt.guitar.amps)
  • Re: EN60065 - safety and audio in/out terminals
    ... I'm working developing an audio equipments that must comply with the ... EN/IEC60065 safety requirements. ... parts and the mains line terminals. ... You will probably have a transformer inside the cabinet. ...
    (sci.electronics.design)

Loading