Re: tube-noob question



On Jun 13, 4:49 pm, Ian Jackson
<IanJacksonRemoveThis...@xxxxxxxxxxxxxxxxx> wrote:
In message <f4pisq$3v...@xxxxxxxxxxxxxxxx>, Scott Dorsey
<klu...@xxxxxxxxx> writes

Ross, NS7F <rjtu...@xxxxxxxxx> wrote:
In a circuit with two 6.3V tubes, can I just series the filaments so
that I can use a 12-13.8V supply? Or are there subtleties that I'm
missing?

You can, but the tube filaments won't last as long because of the turn-on
surge. If it's a circuit where the tubes fail with poor emission long before
the filament fails, that's fine.
--scott

I don't get it. Maybe I'm a bit thick, but why would the turn-on surge
higher? Provided the filament current is the same for both tubes, I
wouldn't have thought that it would have made any difference. In the
good old days, I'm sure that I have connected up 12AX7/12AU7/12AT7
heaters (12.6V centre-tap) to run off 12.6V (pinout =
anode-grid-cathode-heater-heater-anode-grid cathode-heater CT). Would
the switch-on surge be less if they were run connected for 6.3V?

If the tube filaments that are in series are perfectly matched, then
they both see the same turn-on surges. The two halfs of a 12AU7 are by
definition pretty well matched.

But if they aren't perfectly matched, then one heats up a little
faster than the other, there is an unequal stress applied to the tube
filaments causing extra abuse to the guy who heats up first. The guy
who heats up faster will have more resistance than the others, but the
current through all the filaments is by definition the same, and the
hot one will be dissipating more power than the other cooler guys.

If there is a filament transformer, the impedance of the transformer
will lessen the peak current at turn-on. So will other devices that
serve as inrush limiters.

In real life, while filament failures do occur, they are not the most
common cause of a tube's end-of-life. Just in my experience, low
emission, gassy tubes, and interelement shorts are all far more common
failures of the tube. Not to mention the #1 cause, a leaky coupling
capacitor causing a tube to overheat and fail.

Tim.

.



Relevant Pages

  • Re: 813 warm up time
    ... "Long life - not maximum output - is the keynote of transmitting tube ... a 5% decrease in filament voltage will dobule tube life... ...
    (rec.radio.amateur.boatanchors)
  • Re: RAC Bulletin 013-05 Industry Canada Introduces Alternatives to Morse Requirements for HF
    ... I think the old guys who used to have to worry about winding a filament ... choke for an old tube PA are still worried. ... Kim, don't you ever wonder who setup newsgroups for them on their computer, ...
    (rec.radio.amateur.policy)
  • Re: The Duggled Method of using PP OPT to give SE outpur was pentode amplifiers
    ... Since you are not naming the tube used in your amplifier, ... volt DC source and no inductor is assumed in the filament circuit. ... This gives the following for the filament resistance. ... The lower than desired load reduces the audio ...
    (rec.audio.tubes)
  • Re: wiring FrankenVox AC15 for 6AQ5s and 6BQ5s?
    ... It is possible that I'll have to supplement the filament supply as it is. ... variac for the rest of the circuit? ... I know the filament winding (based on the tube compliment of the donor amp) ... As for the rest of the ckt, the PT runs about 255-0-255 without load. ...
    (alt.guitar.amps)