Re: Tech help- Gottlieb System 1 power supply
- From: Mark Clayton <spamuser1604@xxxxxxx>
- Date: Sun, 31 May 2009 17:42:59 -0400
For testing, you can remove SCR101 and see if that
fixes the problem. The SCR is used to short circuit
the power and blow the fuse in case of regulator overvoltage.
Next check the voltage across C1 for about 14 VDC and then check
CR1 and CR2 rectifier diodes.
-Mark
-----
http://pinballpal.com
kactussjack wrote:
I am getting 2.4V instead of 5V. I have replaced Q1 & IC1 with no.
change. I thought I saw a post here where someone changed out
SCR101which fixed the same problem. Can anyone point me in the right
direction?
Thanks.