Re: need help choosing between line level cables



On Tue, 15 Apr 2008 19:02:28 +0100, Eeyore
<rabbitsfriendsandrelations@xxxxxxxxxxx> wrote:



Don Pearce wrote:

Eeyore wrote:
Don Pearce wrote:
"Arny Krueger" <arnyk@xxxxxxxxxx> wrote:
"Eeyore" <rabbitsfriendsandrelations@xxxxxxxxxxx> wrote in

Balanced wiring only gives you an advantage if the
equipment is balanced. With clever wiring it's only
actually necessary for either the 'sending' or
'receiving' equipment to have a balanced input or ouput
but you need to know what you're doing in this case.

I know the strong advantage that balanced inputs give, but what advantage do
you get from an electronically-balanced output driving an unbalanced input?


Provided you have an appropriate balun, like a transformer at the
input, you get all of the advantages.

You don't even need a balun if you wire it to take advantage of the balanced
output. Just take the balaned output (low/cold) to the destination input 'ground'
and the output (high/hot) to the destination input and do not connect the screen
at the destination.

No longer balanced - not even a tiny bit.

It's differential and for all practical purpose does the same job.

No, it isn't. You have one wire shorted to ground, and the other
terminated with an amp input. The two wires are no longer equal and
opposite, so what should be common mode pickup becomes differential
mode.


--

d
.



Relevant Pages

  • Re: need help choosing between line level cables
    ... 'receiving' equipment to have a balanced input or ouput ... You don't even need a balun if you wire it to take advantage of the balanced ... Just take the balaned output to the destination input 'ground' ... so what should be common mode pickup becomes differential ...
    (rec.audio.tech)
  • Re: need help choosing between line level cables
    ... 'receiving' equipment to have a balanced input or ouput ... You don't even need a balun if you wire it to take advantage of the balanced ... Just take the balaned output to the destination input 'ground' ... so what should be common mode pickup becomes differential ...
    (rec.audio.tech)
  • Re: need help choosing between line level cables
    ... 'receiving' equipment to have a balanced input or ouput ... You don't even need a balun if you wire it to take advantage of the balanced ... Just take the balaned output to the destination input 'ground' ... Still, IMM, it would be safer to simply isolate and balance the line conventionally...either with transformers or active circuits on both ends. ...
    (rec.audio.tech)
  • Re: Ping: DC
    ... and all the circuit grounds on the same bolt. ... that ground wire from the cord should be the longest of the ... wall voltage potential. ... ANSI/UL 813-1996 Commercial Audio Equipment ...
    (alt.guitar.amps)
  • Re: Ping: DC
    ... and all the circuit grounds on the same bolt. ... that ground wire from the cord should be the longest of the ... wall voltage potential. ... ANSI/UL 813-1996 Commercial Audio Equipment ...
    (alt.guitar.amps)