Re: How do I arrange drives.



Previously SpreadTooThin <bjobrien62@xxxxxxxxx> wrote:
I need about 10 Terabytes of storage space.
I see that there are 1 Terabyte disks available.

I'm new to RAID, so please...

As I understand it there are different ways to configure drives in a
raid for redundancy...

If there are 8 bites per byte and one bit for parity and / or
redundancy, then do I need 9 drives to have a full 10 Terabytes? or is
that only 8 terabytes?

8. And take into account that HDD manufacturer use correct SI units,
so that TB would be 1,000,000,000,000 Bytes.

You need 11 drives for a 10TB RAID5. You need 12 drives for a
10TB raid6.

In this configuration if one drive fails it can be replaced and its
contents would be rebuilt?

Yes.

Is that a function of the RAID controller?

Among other things, it should be able to do this.

Do RAID systems always use SCSI drives?

No.

Care to point me in the right direction?

If speed is not an issue, you may wanto to condider software
RAID. If speed is an issue, get a 12 port SATA controller.
Currently 3ware and arcea seem to have the best hardware,
and 3ware seem to have the best support and drivers. Stay
away from Adaptec, they produce high-priced trash.

Consider, e.g., these controllers:
http://www.3ware.com/products/serial_ata2-9000.asp
http://www.3ware.com/products/serial_ata2-9650.asp

For hardware RAID you also want to get a spare controller,
since thay can fail as well. For software RAID, that is not
a concern and a software RAID array can typically be used
on an entirely different computer (with enough controller ports)
without loss of ddata. At least under Linux it is not an issue
at all.

As to redundancy, you may consider RAID6, which can survive a
2-disk loss without loss of data, but costs you the capacity
of 2 disks. Also make sure you have a spare disk handy,
operating a RAID array without redundancy is dangerous.

Arno

.



Relevant Pages

  • Re: Windows RAID
    ... But it has only one disk redundancy ... raid10,f3 layouts to get fast reads striped over all the disks. ... is that software RAID can make either RAID 0+1 or RAID 1+0 volumes. ... your first disk failure occurred in the AC pair, ...
    (comp.sys.ibm.pc.hardware.storage)
  • Re: difference between striping using mdadm and LVM
    ... way!), is "thou shalt make a plan for restoring from backups, test ... another bonus of software raid - if your hardware raid card dies, ... additional backups on - I store my other backups on Iomega REV disks. ... is part of the live array, and both data and parity blocks are ...
    (comp.os.linux.misc)
  • Re: DC RAID Configuration
    ... If the machine has 6 spindles then OS/Logs go on a hardware mirror, if 10 then they go on a 4 disk hardware based 0+1 RAID. ... Their DIT is only in the teens in size so the disks themselves could be small, you just need many to get the high IOPS that make AD really run smoothly. ... 30 DCs with 2500 users total, unless the environment had a lot of very heavy use AD apps I would likely be ok for even a single mirror for those DCs. ...
    (microsoft.public.win2000.active_directory)
  • Re: linux raid vs hw raid
    ... old fileserver hardware I have on hand. ... But, as you probably know, these drives are reasonably ... desktop-class drives as JBODs and using mdadm to RAID them. ... want to move to bigger disks. ...
    (comp.os.linux.misc)
  • Re: ASUS P4C800 Deluxe & SATA-2 drives?
    ... > "The P4C800 Deluxe offers the most complete RAID solution. ... A Promise SATA ... transfer bandwidth to be increased according to the number of disks used. ...
    (alt.comp.periphs.mainboard.asus)