Re: Connecting AS/400s
- From: "Kevin Passey" <kev@xxxxxxxxxxxxxxxxxxxxxxxxxxxx>
- Date: Mon, 22 Aug 2005 08:57:29 +0100
Peter - did you call the remote modem via a normal phone to see if it picked
up?
Kevin
"Peter Kinsman" <peter@xxxxxxxxxxxxxxxxxxxx> wrote in message
news:iwkNe.6786$Il.1662@xxxxxxxxxxxxxxxxxxxxxxxxxxxx
> For many years, in order to set up a passthru scenario, I have created a
> line description, an APPC controller and an APPC device, all with
> APPN(*NO). - like IBM Software Technical Document 12313052. This has
always
> worked - eventually - until now, when a Model 400 with a 7857-017 modem,
> which worked perfectly in my office, steadfastly refuses to connect at the
> client. They are using their own modem, but that is also a 7857-017 and
all
> the set-up screens match my own.
> Now we come to the bit that is different. Option 20 on the SETUP menu
> (Option 11 from menu ASSIST) gives options for creating remote hardware -
> but these are created with APPN(*YES)
> Does this represent a change of heart on IBM's part or have I merely
> inherited someone's unorthodox practices?
>
> One of the earliest errors was
> CPA5704 Controller ctrld on line lind not contacted. Link problem ....
> Frames that are being sent by the local system are not reaching the remote
> system, or the response from the remote system is not reaching the local
> system. This could be caused by electrical interference on the network or
> the FRAMERTY parameter is set for data service operation while the line is
> using a voice grade line.
> As we are using the PSTN then that is probably true and changing the
> FRAMERTY parameter produced CPA5902.
>
> Any suggestions would be most welcome as I am running out of ideas.
>
> Peter Kinsman
>
>
.
- Follow-Ups:
- Re: Connecting AS/400s
- From: Peter Kinsman
- Re: Connecting AS/400s
- References:
- Connecting AS/400s
- From: Peter Kinsman
- Connecting AS/400s
- Prev by Date: Re: The problem with the AS/400 is ...
- Next by Date: Re: Emulate SMTP/POP client
- Previous by thread: Re: Connecting AS/400s
- Next by thread: Re: Connecting AS/400s
- Index(es):
Relevant Pages
|
Loading