Re: PCI-1720U with real time windows target
- From: Jan Houska <houska@xxxxxxxxxxxx>
- Date: Thu, 02 Jul 2009 09:11:27 +0200
Hi Joe,
the warning is due to the fact that you have no Scope or other data display block present in your model. Most probably, this has nothing to do with the crash.
To debug the crash, please try to replace the board I/O block (Analog Input, Analog Output or such) with a block that does not touch the board (like Constant). This would help to separate hardware access problem from all other problems possibly existing with your model.
Good Luck, Jan
Joe wrote:
i m using PCI-1720U as my analog output control card.
it can function well if i control by the PCI Advantech utility.
i used real-time windows target as my DAQ function, once i BUILD my file, it will show a result :
### Successful completion of Real-Time Workshop build procedure for model: test1
but when i press "Connect to Target",
command windows will show:
Model test1 loaded
Warning: No data has been selected for uploading.
if i continues press "RUN", the PCI will hang and the Advantech utility can't used to control again. i need to restart my PC again in order to control by utility.
may i know what posibility that will be to cause the WARNING(Warning: No data has been selected for uploading. )..
Thanks
may i know what the
--
--
Jan Houska HUMUSOFT s.r.o.
houska@xxxxxxxxxxxx Pobrezni 20
http://www.humusoft.com 186 00 Praha 8
tel: ++ 420 284 011 730 Czech Republic
fax: ++ 420 284 011 740
.
- Follow-Ups:
- Prev by Date: Re: Discrepancy Between MATLAB and Mathematica PDE Solutions
- Next by Date: Re: use of FOR fucntion and finding values
- Previous by thread: Re: updating handle structure