Re: Trouble with viewing mode MONITOR



Hi Ray, Generally when this happens, the front panel objects are being shifted in position.  This behavior has been documented in a corrective action request (CAR #35885).  The two current workarounds are the following:- Keep the front panel window open.
- Programmatically adjust the front panel position to detect when the window is minimized and then compensate for the position change.  See the attached VI (written for LV 8.5) as an example of this workaround.


WPT Minimize.vi:
http://forums.ni.com/attachments/ni/170/327891/1/WPT Minimize.vi


Adjust Position.PNG:
http://forums.ni.com/attachments/ni/170/327891/2/Adjust Position.PNG
.