Hi Boris,
Since you are using the DAQ Assistant,
the easiest way to software trigger your signal will be using the Trigger and
Gate Express VI. I?ve attached an example VI below using this. It?s set to
trigger on the rising edge with 500 pre and post trigger samples. Another great
example of software trigger at a lower level is the DAQmx example, Cont
Acq&Graph Voltage ? Analog SW Trigger.vi. This example can be found in the
NI Example Finder. To get to it in LabVIEW go to Help >> Find Examples?
>> Hardware Input and Output >> DAQmx >> Analog Measurements
>> Voltage >> Cont Acq&Graph Voltage ? Analog SW Trigger.vi.
Let me know if you have any questions and
take care.
Thanks,
Trigger and Gate Example.vi: