Re: Problems using PCOMM32.DLL Delta Tau PMAC Driver Library



Thanks Brian for your quick response and help.  I had pretty much
the same setup but I wasn't using the string length function to write
to the maxchar input on the call library function node.  Once I
used that configuration I was able to run both a polling routine and a
command terminal in the same while loop.  I guess that wiring the
maximum number of characters as default was causing my memory
problems.  Hopefully once my boss sees the utility of my programs
the money (~$800) might come for the LV drivers from Delta Tau. 
.