Re: Need 66-block help. 1 POTS line, 8 jacks
- From: "Robert L Bass" <RobertLBass@xxxxxxxxxxx>
- Date: Fri, 13 Jun 2008 13:13:08 GMT
"Bill Kearney" wrote:
That and not dialed up those lines... Heh.
Cruel, Bill. :^)
Back to the subject at hand, I used 66-blocks in security systems many years ago. Besides the good advice others have already offered, the OP might want to do something similar to what we did. When dressing the wires to the block, bring each wire past the intended row to the bottom of the block, then bend it around a finger and back up to the terminal. This will leave a loop of extra cable -- very handy should it become necessary at a later date to rearrange the block.
BTW, we used 66-blocks that came mounted to a backboard with a metal cover. A stick-on, magnetic switch concealed beneath the cover provided tamper protection.
--
Regards,
Robert L Bass
==============================>
Bass Home Electronics
4883 Fallcrest Circle
Sarasota · Florida · 34233
http://www.bassburglaralarms.com
Sales & Tech Support 941-925-8650
Customer Service 941-870-2310
Fax 941-870-3252
==============================>
.