Re: Need 66-block help. 1 POTS line, 8 jacks



Bill Kearney wrote:

I get shocked when I touch the left and right connections on the 66

The phone company uses AC voltage to control the line (mainly for ringing). This is normal. You're just not supposed to be touching the wires.

I didn't know about this when I was a kid running an extension up to my room. I didn't have a wire stripper handy so I just used my teeth. Worked great for the first couple of wires... then the phone rang. Knocked me clean off the step ladder. Not to mention the dirty look I got from the dentist that afternoon when he pulled a tiny chunk of insulation outta my teeth...

That and I can recall a contractor trying to squeeze his way into a very tight and hot wiring closet. He neglected to shut off the PBX before attempting this feat. Too many doughnuts, too much sweat and a couple of lines suddenly ringing... and he got QUITE a surprise! Had he not been such an insufferable jackass leading up to that point we probably would have warned him... That and not dialed up those lines... Heh.


An old tech I used to work with at Chubb years ago used to test for phone lines with his tongue. Yech! I've always used a meter. Telus (the "Ma Bell" in our area) puts 52 VDC to all connected lines. When they "zap" the number (disconnect it via computer), the voltage drops to 48 VDC and there's no dial tone. Using Bill's (the old Chubb tech's) method you couldn't distinguish between a valid line and one that's been disconnected... not to mention the rude surprise if anyone decided to ring the number at the appropriate moment... :-)
.



Relevant Pages

  • Re: Buzzing on phone line?
    ... I have tried disconnecting red/green wires from each of the outlets ... Since the repairman wants $90/half hour, I am hoping someone of you ... I can disconnect the wiring from the company line at the outside box ... But BEFORE you do that put your meter on AC volts and see if there's any voltage betwen the two wires or from either wire to a nearby ground, ...
    (alt.home.repair)
  • Re: Using a Laptop from My Car Battery? -- OT
    ... However the wires need to be 50% thicker to carry ... higher-voltage transmission lines often use a bundle of 4 wires spaced a ... The insulators need to be designed for the DC operating voltage plus ... AC grids require all the generators to be phase ...
    (comp.sys.laptops)
  • RE: [SLE] Need help diagnosing hardware problem
    ... which which the wires leave it) to contact the ... Do not, under any conditions, pull the wire out of the connector, ... Since the +3.3 voltage is new, ... (Volts, Ohms, Milliamps.) ...
    (SuSE)
  • Re: Using a Laptop from My Car Battery? -- OT
    ... However the wires need to be 50% thicker to carry ... The insulators need to be designed for the DC operating voltage plus ... Pacific DC Intertie, or the power feed to Vancouver Island), you put ... connection to the grid. ...
    (comp.sys.laptops)
  • Re: Telephone Wiring
    ... Bared wires with a ... dangerous because it was close to the voltage of your heart. ... the hook to perhaps 9 volts or so. ...
    (alt.home.repair)