Re: Bad port on 470-48T switch
- From: Dophi <yilin.wang@xxxxxxxxx>
- Date: Wed, 20 Jun 2007 22:13:17 -0700
On Jun 21, 5:25 am, Ron <pts4...@xxxxxxxxx> wrote:
Even if the bad port is on the base unit? When I put in a new base
unit it will get all MLT and vlan info?
On Jun 20, 11:00 am, Dophi <yilin.w...@xxxxxxxxx> wrote:
On Jun 19, 8:35 am, Ron <pts4...@xxxxxxxxx> wrote:
I have a cascaded stack of 3 of these 470-48T switches that I just put
out. Just put these out about 2 weeks ago and started to migrate from
my old switches to them.
On the base unit, one of the ports is bad, does not light up when I
connect something to it. My question is if I get a replacement
switch, update the software on it to my current software, and then if
I just swap that switch out for a new one will it automatically pull
down all the configs, like vlans, port assignments etc? Or will I
have to set everything up again?
thanks.
The new ES470 will pull all configuration from entire stack.
Or you can use another way to do it.
1. Dump the binary configuration file from the stack to a TFTP
server.
2. On the new ES470, issue "copy tftp config address x.x.x.x filename
yyy unit #".
This command lets you download a specific unit configuration from
TFTP server.
3. Replace the old ES470 with this new one
.
- References:
- Bad port on 470-48T switch
- From: Ron
- Re: Bad port on 470-48T switch
- From: Dophi
- Re: Bad port on 470-48T switch
- From: Ron
- Bad port on 470-48T switch
- Prev by Date: Re: VERY basic HUNT GROUP Q (Nortel Meridian)
- Next by Date: Business Phone System
- Previous by thread: Re: Bad port on 470-48T switch
- Next by thread: stacking a 470-48T and a 470-24T possible?
- Index(es):
Relevant Pages
|
|