Re: Odd PRI problem on 81c



On Tue 04 Apr 2006 11:31:13p, RonB <ronb02@xxxxxxxxxxxxxxx>, wrote:

I was sent out to a site where they've recently noticed that six of
their PRI circuits (all in the same group) are showing "FE DSBL" on a
few of their channels -- one loop *had* quite a few reporting FE
DSBL, but Verizon has cleared most of that circuit while testing. In
most of the loops it only effects the first channel. What's really
odd is that these channels are working (they have no problems with
dropped calls etc.). When I STAT the channels they show IDLE. When I
direct access them with a maintenance set, I get dial tone and I can
call out. When they're busy, I can TRAD them and get the call record
and they show BUSY when STATed. So the problem seems to be a bogus
error report. Verizon Core Group also sees an FE DSBL (or equivalent
report) from their side, but they also note that the channels are
working.

I think the CO switch is a Lucent -- but, so far, no hard
confirmation. They've got the D channels set to NI2, but CO_TYPE is
set to STD. Our in-house engineer thinks that this should probably be
set to ATT instead *if* the CO switch is a Lucent, but he's reluctant
to screw around with a switch that is working, especially since it's
scheduled to go down in a couple weeks for... some kind of
mainenance... I wasn't told why exactly. The PRIs do come through
CSUs and this is Rel 4. The switch was installed in November and no
one noticed this problem until a couple weeks ago -- but that doesn't
necessarily mean the problem didn't exist from the start. The onsite
tech just got back from school and was experimenting with some of the
STAT commands that he had learned there.

At any rate, has anyone ever heard of this problem? It's the first
time I've ever seen something like this. Thanks for any ideas.

Problem solved. Bell Atlantic (aka Verizon Core) hadn't turned the
B-Channel Messaging Service on. Once they added the feature to the PRIs
everything cleared up in a short time (and they could actually see the
status of the B-Channels where, before, everything looked fine to
them). They said that they had had this problem before with Nortel
Option switches. It took a while to get to someone who would actually
listen -- several open tickets -- but once it finally got to the right
tech it was easy.

--
RonB
"There's a story there...somewhere"
.



Relevant Pages

  • Odd PRI problem on 81c
    ... their PRI circuits are showing "FE DSBL" on a ... When I STAT the channels they show IDLE. ... Verizon Core Group also sees an FE DSBL from ... I think the CO switch is a Lucent -- but, so far, no hard confirmation. ...
    (comp.dcom.sys.nortel)
  • Re: FiOS Cable Service in Portland, Oregon Area
    ... I'm currently a Dish HD user, but with the offers right now from Verizon, I may be able to save a whole lottta loot if I switch to the light pipe. ... If I can get the same or more channels with the same or better quality for a better price, then I will probably jump ship. ... Dish has the HD Voom channels. ...
    (alt.tv.tech.hdtv)
  • Re: Odd PRI problem on 81c
    ... I once had a failure of a DMS100 card in a Bell South ... I even had a T1 test set and two site visits from Bell South ... When I STAT the channels they show IDLE. ... I think the CO switch is a Lucent -- but, so far, no hard ...
    (comp.dcom.sys.nortel)
  • Re: FIOS vs Comcast
    ... I am considering switching from Comcast to Verizon. ... bandwidth the particular head end system has available for HD channels. ... October to Verizon Fios for internet & TV. ...
    (alt.tv.tech.hdtv)
  • Re: Is OTA reception the best there is?
    ... that Verizon is receiving from my local TV stations. ... I was in Best Buy this afternoon, and the Verizon salesman was trying ... course, he wasn't aware that digital signals could go over-the-air, so ... Same goes for the national HD cable channels. ...
    (alt.tv.tech.hdtv)