Re: Catalyst 4003 port speeds
- From: selixd <dougselix@xxxxxxxxxxx>
- Date: 8 May 2007 23:24:14 -0700
On Apr 30, 9:05 am, Lovejoy <Lovej...@xxxxxxxxxxxxx> wrote:
I have a strange issue going on with my Cat 4003 and an old Sun box.
The problem is this....One interface, .44 vlan, on the Sun auto-syncs
up on the switch at 100 full, while the second, .64 vlan, auto-syncs at
100 half. If I force the switch port to be 100 full, I get all kinds
of fcs, xmit and rcv errors. The sun box admin checks the interfaces
and says they are both running at 100 full, while the switch port says
the .64 is only 100 half. The Sun box has been configured to only run
at 10 full. I know that Sun was supposedly notorious for not playing
nice with Cisco switches. It could be a bad nic in the Sun, but the
admin says that both the .44 and .64 would be showing errors at the
same time. Are there any suggestions on how to fix this? Do I believe
what the switch is saying or the Sun box?
TIA
Lovejoy
--
===========================================================
This space for lease....
You may also want to check the wire that's running between them. I
have seen plenty of speed mismatches solved by swapping wires. It may
not fix your problem but I have seen it help many times in the past.
.