Re: Re 2: Onbar problem
- From: "Alessandro Vercelli" <alever@xxxxxxxxx>
- Date: Thu, 24 Aug 2006 09:41:05 +0000 (UTC)
Hi Martin,
the IDS 10 guide is more clear, indeed.
I bounced the db several times but in sysconfig table the value was
always /dev/null; when I builded the db LTAPEDEV was /dev/null, and
probably a value is needed to change it and placing spaces is not
accepted.
Many thanks for your help.
Ciao,
Alessandro
"Martin Fuerderer" <MARTINFU@xxxxxxxxxx> wrote in message
news:mailman.349.1156408508.20706.informix-list@xxxxxxxx
Hi,
The same manual, edition for IDS 10 (December 2004) says
in addition:
----------------------------------------------------------------------------------------------
...
Consider leaving these parameter values blank when you use
ON?Bar because the storage manager sets these values.
Warning:
Set LTAPEDEV to /dev/null or leave it blank on UNIX or \dev\nul
<cut>
For more information, see ?Considerations When LTAPEDEV is
Set to Null? on page 6-21.
----------------------------------------------------------------------------------------------
This should be clearer, I guess.
You also can download new documentation at this site
http://www.ibm.com/software/data/informix/pubs/library/ids_100.html
Ciao,
Martin
--