Cadence LVS error



Hi,

I am getting an error while running the LVS in Cadence. The error
message says: The inv schematic has changed after it was last
extracted. si: the netlist did not complete successfully.

I had completed a sucessful LVS check on this schematic some time ago.
No suddenly I see this error. I have not modified any schematics/
layout/ extracted layout.

This error is not limited to onr schematic but all the schematics
present in my library. I am not sure how to resolve this issue.

Can someone please hyelp me find solution for this problem? Any help
is really appreciated.

Thank you,
Pallavi

.



Relevant Pages

  • Re: Cadence LVS error
    ... On Oct 5, 11:51 am, The Master ... so I have no idea why the schematics would ... I would recomend trying to run LVS on a very small simple schematic, ...
    (comp.cad.cadence)
  • Re: Cadence LVS error
    ... On Fri, 5 Oct 2007, pallavi wrote: ... Further in your post, you mention that you made no schematic edits, so I have no idea why the schematics would suddenly need to have this done again. ... I would recomend trying to run LVS on a very small simple schematic, and see if the "check and save" works... ... then I have no idea what would have caused your entire library to mess up like that. ...
    (comp.cad.cadence)
  • Re: cellView Author property?
    ... Cadence enough yet to be proficient. ... include in my schematics that use ilLabels to display the cell view ... cellView properties is the author of the schematic or the last person ...
    (comp.cad.cadence)
  • cellView Author property?
    ... Cadence enough yet to be proficient. ... include in my schematics that use ilLabels to display the cell view ... cellView properties is the author of the schematic or the last person ...
    (comp.cad.cadence)