Re: about IEWL parameters or so



In <LISTSERV%200805230552163839.015B@xxxxxxxxxxx>, on 05/23/2008
at 05:52 AM, K Zafirop <kzafiropoulos@xxxxxxxxxxx> said:

In IEWL link-edit proceduresITYM bind procedures.

PARM='XREF,LIST,AMODE(31),RMODE(ANY),CALL,MAP,LET'.

Note the LET.

I think that the member should not be replaced in such a case.

Then don't specify LET.

Is there any parameter in order to prevent the
replacement of a member in load library after an unsuccessful link-edit?

You specified a parameter to cause it to replace a member that it
otherwise would not have replaced. Get rid of the LET and it will do what
you want.

--
Shmuel (Seymour J.) Metz, SysProg and JOAT
ISO position; see <http://patriot.net/~shmuel/resume/brief.html>
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to listserv@xxxxxxxxxxx with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

.



Relevant Pages

  • about IEWL parameters or so
    ... In IEWL link-edit procedures we have specified for parameters ... I think that the member should not be ... replacement of a member in load library after an unsuccessful link-edit? ... For IBM-MAIN subscribe / signoff / archive access instructions, ...
    (bit.listserv.ibm-main)
  • Re: Difference between DISP=NEW and MOD for a PDS member?
    ... DISP=NEW fails if the PDS already exists and a member name is ... partitioned data set extended, and you also specify a member name in ...
    (bit.listserv.ibm-main)
  • Re: Difference between DISP=NEW and MOD for a PDS member?
    ... partitioned data set extended, and you also specify a member name in ... the member name must not already exist. ... When you specify DISP=OLD for a PDS or a PDSE, and you also specify a member ...
    (bit.listserv.ibm-main)
  • Re: Problem with winmm.dll under Win2000/XP
    ... Either specify your question clearly, and with adequate information, or ... Control identifier of the desired control. ... This member is used with the ... > without any Problem under Windows 95/98 has a big Problem with Windows ...
    (microsoft.public.vb.winapi)
  • Re: Difference between DISP=NEW and MOD for a PDS member?
    ... the suboperands of DISP relate to the member. ... That confusing paragraph which implied that a data set could exist already ... and you also specify a member name in ... obviously I was concentrating on the only on first suboperand of the DISP ...
    (bit.listserv.ibm-main)