Gary,
That's great information, thanks. We are not doing loads on activates. We do all the activates and then loads. We are trying to stress hardware with this test. Looks like we'll have to go a different direction.
Thanks,
Chris Burgess
EMC²
where information lives
Phone: 1-800-445-2588 x42149
1-508-249-2149
Pager: 1-877-443-8447
Fax: 1-508-544-2076
Email: burgess_christopher@xxxxxxx
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@xxxxxxxxxxx] On Behalf Of Diehl, Gary (MVSSupport)
Sent: Wednesday, October 31, 2007 3:41 PM
To: IBM-MAIN@xxxxxxxxxxx
Subject: Re: CNZ9003I Message
Chris,
Peter Relson or John Eels might be able to shed more light on this, however, "tuning a sysplex to allow 15 images to IPL directly into the same PLEX at the same time" may be a technically impossible goal with current model software and hardware.
And as far as I am aware, the HMC doesn't have a "wait x seconds before loading upon activation of a reset profile" so having them all auto-load after a POR or activation of the CEC probably isn't going to get you the results you seek. At best, I'd expect two to enter the PLEX, one to go to "la la land", and the other 12 to wait state. YMMV.
That's a difficult and worthy goal you've selected. I wish you the best of luck with it!
Gary Diehl
MVS Support
"The glass is neither half full or half empty; the engineer who designed the glass simply allowed for a 100% increase in fluid storage."
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@xxxxxxxxxxx] On Behalf Of Chris Burgess
Sent: Wednesday, October 31, 2007 11:26 AM
To: IBM-MAIN@xxxxxxxxxxx
Subject: Re: CNZ9003I Message
Thanks Gary that is excellent information. We are actually a test lab and we are trying to IPL 15 LPARs at one shot. At this point we have not be able to get them all up in a sysplex environment. I am trying to figure the best way to tune the sysplex to make that happen.
Thanks,
Chris Burgess
EMC²
where information lives
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to listserv@xxxxxxxxxxx with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to listserv@xxxxxxxxxxx with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
.
- References:
- CNZ9003I Message
- From: Chris Burgess
- Re: CNZ9003I Message
- From: Diehl, Gary , MVSSupport
- Re: CNZ9003I Message
- From: Chris Burgess
- Re: CNZ9003I Message
- From: Diehl, Gary , MVSSupport
- CNZ9003I Message
- Prev by Date: Re: IBM Supported JES2 Dynamic Exit Reload
- Next by Date: Re: PL/S ??
- Previous by thread: Re: CNZ9003I Message
- Next by thread: Re: CNZ9003I Message
- Index(es):
Relevant Pages
|