Chris Moore wrote:
Hello! My recently purchased foreclosed home has a Power832 system
installed. To the best of my (limited) knowledge, I have a PC5580Z
keypad (photo here: http://flickr.com/photos/cdmwebs/441461942/in/set-72157600039220788/)
and a PC5010 control board. I had zero information on it, so I did
some Googling and found the installation manual, operating manual,
keypad manual and programming worksheet. This is all well and good so
far, but I've come to discover that the programming process seems to
be somewhat complex.

Actually, DSC is one of the easiest panels to program (for most rocket scientists). :-)



My setup seems pretty simple to me, three doors (front, back and
garage entry), garage attic, motion in living/dining common areas,
carbon monoxide detector and glass break in the garage. It's setup
like this:

Zone 01 - Front Door (Entry/Exit)
Zone 02 - Read Door
Zone 03 - Garage Entry Door
Zone 04 - Garage Attic Door
Zone 05 - Motion
Zone 06 - CO Detector
Zone 07 - Garage Glass Break
Zone 08 - Null

What is the bare minimum I need to program to get this working? The
programming worksheet has all kinds of stuff that I'm not even sure is
relevant.

Can you even access installer level programming?? If so, you'll want to reset the installer and master codes. You might also want to make sure your siren time-out is set at four minutes. As for actual zone programming, the zone options are detailed in the programming work sheets.



Bonus: How hard would it be for me to upgrade the keypad to a newer
LCD version?

Simple. Power down your system. Remove keypad from wall. Remove four wires from terminal block. Wire up new keypad, and mount on wall. Power up system. Programming the LCD descriptors can be a bit time consuming if you're using the "finger" method (keypad programming). It's a bit quicker using DLS.
.



Relevant Pages

  • Re: DSC Power832
    ... keypad manual and programming worksheet. ... Zone 03 - Garage Entry Door ... Can you even access installer level programming?? ...
    (alt.security.alarms)
  • Re: Help needed MAGELLAN MG5050
    ... control panel) but the keypad keeps on showing message "Zone01 open". ... My multimeter indicated that the zone is closed - WHAT AM I DOING ... If you're having problems understanding programming via the manual, I would suggest that you might be less frustrated by calling in a pro to do it for you. ...
    (alt.security.alarms)
  • Re: DSC Power832
    ... There are several versions of the LCD keypad. ... holy it is the fastest and best method of programming a panel. ... garage entry), garage attic, motion in living/dining common areas, ... Zone 02 - Read Door ...
    (alt.security.alarms)
  • Re: Cheat sheet for Ademco Vista 20-P installation
    ... There are no dip switches on a 6160RF keypad. ... reading and web research I was able to program the panel to my liking. ... alarm installers time in setting up a new Vista system. ... Zone 1 MUST have an EOL resistor installed. ...
    (alt.security.alarms)
  • Cheat sheet for Ademco Vista 20-P installation
    ... Fellow Do-it-yourself Home Security System Installers, ... alarm installers time in setting up a new Vista system. ... Zone 1 MUST have an EOL resistor installed. ... I recommend the 6160RF keypad as it is alphanumeric AND it provides ...
    (alt.security.alarms)