Re: dsc 832 problems



If the system is partitioned and one of the partitions is armed or a 24 hour
zone is in alarm then I believe you won't be able to enter programming. I
don't think you can enter programming if the system is communicating or
attempting to communicate either

Doug.


--

"dani" <marianroscatu@xxxxxxxxx> wrote in message
news:a6f60cbb-cdf8-4c6b-96fd-947951c76f4f@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Hi,
I have a DSC 832 panel wich don't enter programming. Right after i
type *8 it makes an error sound (long beep); typing the installer code
is useless. First time i got this, i had already entered programming
a couple of seconds ago and after a couple of weeks, the problem went
away. Two days ago i was working on that system and today i got that
error after *8 again.
Also I am skeptical about doing a hardware reset, since I won't be
able to reprogam the panel if the reset won't solve te problem.

I really need help on this.

A minor problem with DSC 832: some reporting codes willl reprogram
once in a while (i.e. CID programmed code 1401 goes to 14C1). 2
different 832 panels have done that. Can you explain?


.



Relevant Pages

  • Re: Compass Software
    ... > local dealers and ask them to supply you with access the Honeywell Dealer ... > programming though, and there's no way for you to alter critical functions. ... and configured and ready to go and doesn't need any end-user or dealer ... on an Alarm Panel either, you can only muck with parameters. ...
    (alt.security.alarms)
  • Re: Brinks v Jim Rojas New Motion
    ... I purchased a home with a brinks panel already installed from the previous owner about 2 yrs ago. ... Can anyone that's ever used a Brinks/Scantronics handheld programmer tell me some other things that it is capable of doing on a BHS2000 panel? ... Unlike typical programming where you toggle things on & off, or change what you want that field to do, each of their field may control a critical function that has nothing to do with the fields name. ...
    (alt.security.alarms)
  • Re: Brinks BHS2000D Hack
    ... I purchased a home with a brinks panel already installed from the previous owner about 2 yrs ago. ... Can anyone that's ever used a Brinks/Scantronics handheld programmer tell me some other things that it is capable of doing on a BHS2000 panel? ... Unlike typical programming where you toggle things on & off, or change what you want that field to do, each of their field may control a critical function that has nothing to do with the fields name. ...
    (alt.security.alarms)
  • Re: Computer virus???
    ... That is what the installer code is for. ... can change any of the information in the panel is to hardware default ... as they can for any other company to take away the client. ... refuse to use it and when im worried about some one messing with programming ...
    (alt.security.alarms)
  • Re: notifier verifire softwarw
    ... I would have to agree with you that compared to Edwards, Notifier has, ... at least allowed programming from the front panel. ... If you have the correct programming software you can ... Compare that to, say, an EST-3 panel. ...
    (alt.security.alarms)