Bob Sisson wrote:
You may think its easy...but it baffles me...I can program the alarm zone
stuff, and the X10 automation stuff in my automation controler, but the X10
stuff in the alarm controller makes no sense to me...
Just call bAss... He says a monkey can do it.
Anyway.
You are going to have to map out two output numbers in *79 (01 & 02)
then assign X-10 addresses under "unit number".
Then go to *80 and define how you want each output number (01 & 02) is
triggered (for instance: all zones type 1 fire, zone 5 garage door, or
a list of individual zones). And what you want it to do:
0 = off
1 = Close for 2 sec
2 = Stay Closed
etc....
.