Re: 5540 Silent Knight Software Question



Bill,

I can't seem to decipher what you're trying to accomplish.

It seems as though you haven't determined if the panel is sending 4x2, CID or SIA.

If you want to find the account number of the panel, please record an alarm session to a laptop as a wav file. After 5 seconds of listening to it I could determine if it's 4x2, CID or SIA, and in 10 minutes I could give you the account number and alarm if 4x2 or CID, SIA will take longer, more equipment needed.

If you're trying to download/upload to/from the panel and don't have the account number, good luck, then see the last paragraph and continue.

If you could explain precisely from the beginning what your problem is and not your various thoughts on cobbling something together and what it could do for you, we may be able solve this for you.

After many years of trouble shooting technical problems, I've found it best not to listen to someone else's analysis of the problem but to listen to their description of what's happening. I won't even trust my best college's analysis of the situation, even though I know he's younger and brighter than I, sometimes one person can look at a problem for hours, and another can walk in and see the fault in 5 seconds.

So Bill, give use the description of your problem, what you want to accomplish, and sit back and watch all of us nail this for ya.



Bill wrote:
If the panel sends an alarm in DTMF and also sends it's account number in DTMF then I could capture those tones as it is sending to the CS.
Then I could run the .wav file through a DTMF decode and I would have the account number.
I'm not sure if the panel is set to send SIA or FSK. It has both available in the programming and I don't know what they set it to.


.



Relevant Pages

  • Re: DSC GS3055-I Radio
    ... have the central set up two account numbers. ... GS3055-I and the panel send CID if all the signals come in on one ...
    (alt.security.alarms)
  • Re: UPlink 2550
    ... All it does is trick the panel into thinking it's connected to pots then ... It's full reporting and passes CID and SIA from the telco port on ...
    (alt.security.alarms)
  • Re: UPlink 2550
    ... All it does is trick the panel into thinking it's connected to pots then ... passes the CID or SIA through, they say they are working on remote ...
    (alt.security.alarms)
  • Re: regional setting
    ... account has the symptoms of not allowing regional setting via the control ... panel GUI interface. ... This ensures that the date separator and the date format are ...
    (microsoft.public.windowsxp.help_and_support)
  • Re: 5540 Silent Knight Software Question
    ... Protection one monitored the system, but the owners never used the system. ... I found that I needed a 5530 modem made by Silent Knight. ... existing account. ... The second problem is that the phone number programmed in the panel goes to ...
    (alt.security.alarms)